Paper: |
LISA Technology Package Flight Hardware Test Campaign |
Volume: |
467, 9th LISA Symposium |
Page: |
141 |
Authors: |
Cervantes, F. G.; Flatscher, R.; Gerardi, D.; Burkhardt, J.; Gerndt, R.; Nofrarias, M.; Reiche, J.; Heinzel, G.; Danzmann, K.; Boté, L. G.; Martín, V.; Mateos, I.; Lobo, A. |
Abstract: |
We present performance measurements of the optical metrology system that will fly as part of the
LISA Technology Package experiment. These results were obtained during thermal-vacuum testing of
the LISA Pathfinder spacecraft. The optical metrology flight units were integrated in the
spacecraft and operated in an artificial space environment at the expected in-orbit thermal limits
of 30.5 °C and 9.5 °C. An interferometer performance of better
than 6.4 pm/√Hz in test mass displacement, and
1 nrad/√Hz in test mass angular motion was demonstrated over the entire
measurement frequency band of 3-30 mHz. |
|
|
|
|